Skip to content

Nuclear data explorer · reaction

7Be(n,p)7Li

All 19 EXFOR datasets of this reaction: who measured it, where and when, what they measured and over which energies.

Gamow window and the gap

Every dataset EXFOR holds for this reaction, drawn by the energies it covers, against the energies a star uses.

19 datasets in 8 EXFOR entries, 1955–2021 · 3 without an energy range, not drawn

Temperature
Lowest energy in EXFOR
17.9 meV
Hanna, 1955; Gledenov et al., 1987; KOEHLER et al., 1989; Damone et al., 2018; Tomandl et al., 2019 · σ · 23291.002
Maxwellian averages measured
None in EXFOR
Rate from energies not in EXFOR
4.1%
at kT = 68.9 keV, smooth estimate
1 meV100 meV10 eV1 keV100 keV10 MeVCentre-of-mass energy (keV)kT = 68.9 keVσσ→Eₓωγother
  • Energies that matter at kT = 68.9 keV
  • Outlined bars are shown but not counted (the rule is under “How these numbers are made”).
  • A diamond is a dataset at a single energy. Bars running off the right edge continue to higher energies.
The datasets of the gap map, by quantity
The datasets of the gap map, by quantity
QuantityDatasetsE_cm range (keV)
σcross section88.74 meV – 1.75 MeV
σ→Eₓpartial522.1 meV – 2.45 MeV
ωγresonance strength111.4 keV – 3.1 MeV
…other222.1 meV – 22.1 meV
How these numbers are made

Lowest measured energy, everywhere in the data explorer: the lowest centre-of-mass energy at which a dataset in EXFOR measures the reaction itself (cross section, S-factor, angular distribution, yield or resonance strength), judged point by point. A point counts when it is a value, not an upper or lower limit, when it lies at least one standard deviation above zero, and when its energy is physical: at least 1 keV for charged particles, and not below the threshold of an endothermic reaction. Not counted: extrapolated, calculated, evaluated or derived values; superseded, deleted or preliminary data; ratios; a single S-factor value, which in EXFOR is a fit result; and indirect methods (Trojan horse, Coulomb dissociation, ANC, surrogate reactions), recognized from EXFOR's method and analysis codes, their text and the title. Frame and unit errors of EXFOR are corrected first, and values the literature shows to be upper limits are read as limits, from a list that gives the evidence for each. Datasets that reach the same energy within 0.5% are all credited, earliest first. Rate from energies not in EXFOR: the share of the rate integrand at that temperature outside the energy ranges the counted datasets cover (from their lowest measured point to their highest), with a constant S-factor (σ ∝ S(E₀)/E · e^−2πη, so the integrand is e^(−E/kT − 2πη)); for a neutron capture, σ ∝ 1/v. Resonances make the real integrand lumpy, so read it as a smooth baseline.

Loading the datasets…